Fluke 117 Digital Multimeter: The choice for commercial applications
Đồng hồ vạn năng FLuke 117
Tính năng Đồng hồ vạn năng FLuke 117
VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30-seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
CAT III 600 V safety rated
Thông số kỹ thuật đồng hồ vạn năng FLuke 117
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital:
6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Thông số kỹ thuật đồng hồ vạn năng FLuke 117
Accuracy Specifications
DC millivolts
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.00 V / 0.1 V
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:
600.0 V
Resolution:
0.1 V
Accuracy:
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.0 V / 0.1 V
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:
600 Ω
Resolution:
1 Ω
Accuracy:
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:
600.0 Ω / 0.1 Ω
Range/Resolution:
6.000 kΩ / 0.001 kΩ
Range/Resolution:
60.00 kΩ / 0.01 kΩ
Range/Resolution:
600.0 kΩ / 0.1 kΩ
Range/Resolution:
6.000 MΩ / 0.001 MΩ
Accuracy:
0.9 % + 1
Range/Resolution:
40.00 MΩ / 0.01 MΩ
Accuracy:
5 % + 2
Diode Test
Range/Resolution:
2.000 V / 0.001 V
Accuracy:
0.9% + 2
Capacitance
Range/Resolution:
1000 nF / 1 nF
Range/Resolution:
10.00 μF / 0.01 μF
Range/Resolution:
100.0 μF / 0.1 μF
Range/Resolution:
9999 μF / 1 μF
Range/Resolution:
100 μF to 1000 μF
Accuracy:
1.9% + 2
Range/Resolution:
> 1000 μF
Accuracy:
5% + 20%
LoZ capacitance
Range:
1 nF to 500 μF
Accuracy:
10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:
6.000 A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:
6.000 A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:
99.99 Hz / 0.01 Hz
Range/Resolution:
999.99 Hz / 0.1 Hz
Range/Resolution:
9.999 Hz / 0.001 Hz
Range/Resolution:
50.00 Hz / 0.01 Hz
Accuracy:
0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F